Basic Info.
Oil Outlet Caliber
1 Inch
Type
Self Closure Fuel Nozzle
Application
Automotive Exhaust System
Packing
1 PC a Box, 10 PCS a Carton
Product Name
Fuel Nozzle with Meter
Transport Package
1 Piece for Individual Boxed.
Specification
10 pcs/ carton
Product Description
Measure Fuel Nozzle
This flowmeter is developed on the latest technology in foreign countries. It surpasses our previous understanding of turbine flowmeters, and the repeatability is within plus or minus 0.2%. It is one of the most mature liquid measurement technologies in the world. It has four functions: automatic conversion, instantaneous flow, single measurement and cumulative measurement. It is also possible to reset the coefficients according to the environment to match the flow meter to the existing flow environment.
Technical parameters:
Applicable medium: diesel, gasoline, kerosene.
Flow range: 15-75L/min
Import 1 inch internal thread, about 31mm,
With 360° rotating 1 inch cannula connector, insert inner diameter 25mm hose
Exit 15/16 inches, about 23.8mm
Measurement accuracy: ±1% repeatability: ±0.2%
Working pressure: 0.25Mpa Ambient temperature: -20~55°C
Working voltage: 2.3-3.3V Standby time: 2 years
Single count: 0.000-9999.9 Total cumulative number: 0.000-99999.9
Unit of measurement: liter / L
Coefficient debugging method: the original coefficient is 1.000
According to the [-] button on the right side of the flowmeter surface, you can reduce the coefficient and increase the actual oil output.
According to the [+] button on the right side of the flowmeter surface, you can increase the coefficient and reduce the actual oil output.
When adjusting to the desired factor, release the button and automatically return to the standby screen after 3 seconds.
For example: to add 100 liters of oil, the actual output of 102 liters of oil, the flowmeter shows 100 liters, then how to adjust to the flowmeter display 100 liters, the actual oil is also 100 liters, follow the following methods:
Press the [+] key to increase the coefficient to 1.020. Release the button. After 3 seconds, it will automatically return to the standby interface. At this time, the flow meter can display 100 liters and the actual oil output is 100 liters. Conversely, reduce the coefficient and increase the actual oil output.
single cumulative zero and view total accumulation, coefficient, instantaneous flow:
Single cumulative clear: Press and hold the RESET button for 3 seconds to clear the single accumulation;
Query total accumulation: Press RESET+CAL at the same time to view the total accumulation;
Query coefficient: Press and hold RESET+CAL at the same time to view the current coefficient;
View instantaneous flow: Press CAL to switch, you can view instantaneous flow and single accumulation.
Faults and treatment methods:
1. The screen does not display: check if the battery has power, or if the battery is in good contact;
2. Do not count: check whether the sensor is displaced, or there is debris in the magnet on the impeller, remove it and clean it;
3. Inaccurate measurement: check whether the sensor is displaced, or there is debris in the magnet on the impeller, remove impurities, and re-correct the coefficient;
4. Digital flashing: Replace the battery.
Address:
1514 Yihe Building, Cangzhou, Hebei
Business Type:
Trading Company
Business Range:
Transportation
Management System Certification:
ISO 9001
Company Introduction:
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.